Customization: | Available |
---|---|
After-sales Service: | 24-Hour Customer Service Hotline |
Type: | Vickers Hardness Tester |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Overview
The VHVS-1000Z Visual Direct-Reading Vickers Hardness Tester is a marvel of modern engineering, featuring an industrial control integrated operating system seamlessly within its main unit. Every operation is effortlessly executed as the computer orchestrates the main unit's functionalities. Test images and results are vividly presented on the computer screen, offering an intuitive experience that enhances parameter settings and result displays. This innovation not only simplifies operations but also mitigates the eye strain typically caused by microscope light sources, significantly reducing visual fatigue. Furthermore, the advanced automatic measurement functionality embedded in the software ensures precision by minimizing measurement errors.
Product Introduction
1.The machine's robust fuselage is expertly crafted from a single piece of high-quality cast iron and refined with automotive baking paint technology, resulting in an aesthetically pleasing, smooth, and elegant appearance.
2.Highlight configurations: This state-of-the-art equipment boasts dual operation modes and a dual optical path system. With an industrial control integrated computer at its core, it retains traditional touch screen and micrometer operation modes, offering users a plethora of operation and calibration options for enhanced flexibility.
3.The industrial control integrated computer empowers users with advanced functionalities, including turret magnification adjustment, screen brightness control, indentation video display, image capturing and storage, data analysis, and seamless report exporting.
4.While automatic measurement is standard, the machine offers three manual measurement techniques: four-side measurement, diagonal measurement, and four-point measurement, with the freedom to choose any sequence of vertex selection.
5.Featuring dual calibration types: optical calibration and (manual/automatic) hardness block calibration. The hardness blocks facilitate multiple averaging and flexible calibration using unlimited standard blocks, ensuring optimal measurement through segmented calibration. The software automatically selects the best calibration coefficient tailored to different resolutions, objectives, and loads.
6.The system provides real-time pixel and physical distance calculations of the indentation diagonal, delivering instant HV/HK values under the current load.
7.Stay updated with the real-time display of the hardness tester's operational status, including current indenter/objective, holding time, and loading force magnitude.
8.Manual distance measurement between two points is possible; multiple sets of distances can simultaneously be displayed on the video or image for comprehensive analysis.
9.Efficiently mark test point information individually or per customer specifications. Test point identification is conveniently shown in the test value sequence list and indentation diagram, streamlining queries and aiding in subsequent analysis and processing.
10.Utilize global hardness conversion standards such as GB, DIN, ISO, and ASTM to achieve seamless mutual conversions among various hardness values: Vickers HV, Knoop HK; Rockwell: HRC, HRA, HRB, HRD, HRE, HRF, HRG, HRK; superficial Rockwell: HR15N, HR30N, HR45N, HR15T, HR30T, HR45T; Brinell HBS, Brinell HBW.
11.For measuring the hardened layer path sequence, enjoy the versatility of multiple flexible initialization setting modes. The system saves and imports previous path sequences automatically, with options to save measurement paths separately for future reloading.
12.The system intelligently generates corresponding hardened layer depth values and hardness change curves from the measurement results of the path sequence.
13.Select from a myriad of analysis modes for measurement data, with the capability to include all results in comprehensive graphic reports. Customize the content and format of these reports flexibly, with automated generation of word and excel documents.
14.Set passwords and define management rights, ensuring ordinary operators can only conduct hardness measurements as per pre-set configurations, maintaining system integrity.
15.Available in versatile software versions, users can opt for either Chinese or English, catering to diverse language preferences.
16.The machine's accuracy strictly adheres to the prestigious standards of GB/T4340.2, ISO6507-2, and ASTM E384, ensuring unmatched reliability.
Scope Of Application
1.Expertly designed for a broad range of materials, including ferrous metals, non-ferrous metals, IC wafers, surface coatings, and laminated metals.
2.Apt for various non-metallic materials such as glass, ceramics, agate, gemstones, and thin plastics.
3. Discover the precision of our state-of-the-art hardness testing capabilities, designed specifically for evaluating the depth and gradient of carburized and quenched layers with unmatched accuracy.
4. Perfectly tailored for the precise micro Vickers hardness measurement, our machine excels when working with parallel planes, micro parts, and ultra-thin components, ensuring meticulous results every time.
Technical Specifications
Model |
VHVS-1000Z |
Measurement Range |
5-5000HV |
Test Forces |
0.09807,0.2452,0.4904,0.9807,1.961,2.942,4.904,9.807N (10,25,50,100,200,300,500,1000g) |
Data Input Method |
Automatic
|
Turret Mode |
Automatic
|
Maximum Allowable Height Of The Test Piece |
200mm |
Distance From Indenter Center To Machine Wall |
130mm |
XY Worktable Size |
100*100mm |
XY Worktable Travel |
25*25mm |
XY Worktable Minimum Unit |
0.01mm |
Lens Magnifications |
10×,40× |
Magnification |
100×,400× |
Minimum Step Distance |
0.025μm |
Hardness Resolution |
0.1HV |
Power Supply |
AC 220V,50Hz |
Dimensions |
610*330*750mm |
Weight |
75kg |
Standard Configuration Of Accessories
XY Worktable |
One piece |
Fine Shaft Test Stand |
One piece |
Thin Sheet Test Stand |
One piece |
Small flat-jaw pliers test stage |
One piece |
Large V-shaped block |
One piece |
Small V-shaped block |
One piece |
Diamond Vickers Indenter |
One piece |
Standard Microhardness Blocks |
Two pieces |
Industrial control integrated computer |
One set |
8-inch touch screen operation panel |
One piece |
Image analysis software |
One set |
Standard graduated scale |
One piece |
Dongle |
One piece |
Data cable |
One piece |
Camera (built-in) |
|
|
The above is the standard configuration. Please note that actual products are subject to the physical objects, ensuring you receive exactly what is needed for your specific requirements.